MIL-H-80055B
e.
Heating stations.
(1) Bench mounted or portable (specify details of portability).
(2) Multiple heating stations of the same or different KW
output rating for multiple operations.
(3) Push button or foot switch with safety guard, nine foot long
three wire rubber covered cable, and twist lock plug with
receptacle for manual control.
* (4) High frequency output matching transformer.
(a) Fixed ratio isolating type, water cooled.
(b) Variable ratio isolating type, water cooled.
(c) Variable ratio auto-transformer type, water cooled.
(5) Tap switch for use with (4) (c) above.
(6) Process timer (specify details of timing requirement).
(7) Meters installed on heating station.
(8) Quench system.
(9) Solenoid valve to allow water to flow through work coil
when heat is on, with protection to ensure the presence
of cooling water flow before heat can be applied.
(10) Heat "ON-OFF" switch and indicating lights.
f.
MG set, control station and heating station on common base.
Hours of operation meter installed on MG set.
g.
h.
Other options as specified.
* 3.8 Suppression of radio interference. When required, radio interference
suppression shall be as specified (see 6.2.1).
* 3.9 Moisture and funqus resistant treatment. When required, moisture
and fungus resistant treatment shall be as specified (see 6.2.1).
3.10 Portability. Unless otherwise specified (see 6.2.1), portability
shall be as indicated in 3.2.8 and 3.5.2.