MIL-H-80055B
h. Heat run, load and temperature test - four hour test run may be
extended until consecutive readings one half hour apart indicate stable
temperature.
i.
High potential test.
Motor input - volts, amps, kilowatts.
j.
Generator output - volts, amps, kilowatts, and vars.
k.
Generator field input - volts, amps.
l.
m.
Air gap c earances.
n.
Accelerat ng time in seconds.
The overall efficiency, Insulation test, cooling systems, endurance tests,
and vibration tests requirements shall be performed and the load and
temperature test shall be varied to demonstrate the ability of the multiple
tapped capacitor to provide for power factor correction. The output
frequency shall be measured.
* 4.6.5 Suppression of radio interference test. Induction heaters having
radio interference suppression shall be tested for compliance with 3.8.
* 4.7 Packaging inspection. Packaging shall be inspected to determine
compliance with the requirements of Section 5.
PACKAGING
5.
* 5.1 Preservation, packing and marking. Unless otherwise specified (see
6.2.1), preservation, packing and marking shall conform to the requirements
of MIL-STD-1188.
NOTES
6.
6.1 Intended use. The induction heating equipment described herein is
to be used to produce localized heating of various degrees of intensity
for hardening, annealing, brazing, or soldering of metals or some related
application of the above.
6.2 Orderin data. Purchasers should exercise any desired options
offered herein and procurement documents should specify the following: