MIL-H-80055B
on circuits above 230 volts shall be provided with means of rapidly
draining the stored charge. In addition to other safety requirements
specified herein, the induction heaters shall conform to the applicable
requirements of NFPA Standard No. 70. The heaters shall comply with the
standards promulgated under OSHA applicable to the heater itself. Addi-
tional safety and health requirements shall be as specified (see 6.2.1
and 6.4).
* 3.2.3 Protective devices. Unless otherwise specified (see 6.2.1),
protective devices specified in 3.2.3.1 through 3.2.3.3 shall be furnished
and installed on each MG set. In addition, where applicable, all protec-
tive devices shall terminate into a protective control point-or unit. The
control point or unit shall include provisions for determining that pro-
tective devices are operative, determining protective devices in operation,
and shall include manual reset devices such as switches or push buttons to
prevent automatic restarting.
3.2.3.1 Devices for all sizes of MG sets.
A vibration eliminator base is to isolate the MG set from the floor
a.
or its mounting plate.
b.
A bearing electrical insulator to prevent circulating shaft currents
during operation.
c.
An air temperature switch to stop operation in event of excessive
internal air temperatures.
d.
A water pressure switch on water cooled units to stop operation
in event of inadequate water supply.
3.2.3.2 Devices for control stations.
Fuses to protect the control, high frequency meter, and field
a.
supply circuits.
3.2.3.3 Devices for heating stations.
A water pressure switch to stop operation in the event of inade-
a.
quate water supply.
A water pressure gage to indicate water pressure in the cooling
b.
water circuits.
c.
A strainer for inlet water to prevent entry of foreign matter into
the cooling water circuits. Locate in an accessible position.
d.
Sight drains to provide evidence of cooling water being properly
provided to critical components.